Package Size Constraints
We are limited to the size of package we can process. Due to variations in equipment design, the sizes differ from North to South ends of the building. Dimensions in the Part Dimension column are actual body sizes, not including the carrier.
Electrocoat
Part Dimension
Assumptions & Notes
Height 75" (1905mm)
Width 80" (2032mm)
Length 276" (7010mm)
South
Part Dimension
Assumptions & Notes
Height 60" (1524mm) The dimension at left is only the part to be painted, not including the carrier.
Your part rests on our carrier. The bottom of your part is located 18" (457mm) from the floor. This allows for paint coverage to the bottom corner of your part.
This value, 60", only provides 1" (25.4mm) clearance to the flash-off's overhead lamps, which is OK for convection-only. If your project requires IR or FastFlash™ lamps, decrease this dimension to 56" (1422mm).
Width 73" (1880mm) Taken at the roof. The door area can be up to 85" (2159mm) wide.
Length 17'-10" (5436mm) Limited by conveyor turning radii.
North
Height 56" (1422mm) The dimension at left is only the part to be painted, not including the carrier.
Your part rests on our carrier. The bottom of your part is located 18" (457mm) from the floor. This allows for paint coverage to the bottom corner of your part..
This value, 56", only provides 1" (25.4mm) clearance to the flash-off's overhead lamps, which is OK for convection-only. If your project requires lamps, decrease this dimension to 52" (1321mm).
Width 67" (1727mm) Taken at the roof. The door area can be up to 95" (2413mm) wide.
Length 16'-0" (4877mm) Limited by conveyor turning radii.